Difference between revisions of "Retina Scan Identd"
From WPKG | Open Source Software Deployment and Distribution
Line 18: | Line 18: | ||
<source lang="xml"> | <source lang="xml"> | ||
+ | <?xml version="1.0" encoding="UTF-8"?> | ||
+ | |||
+ | <!-- CHANGE LOG ----------------------------------------------- | ||
+ | DATE USER EDIT | ||
+ | |||
+ | ---------------------------------------------------------------> | ||
+ | |||
+ | <packages:packages xmlns:packages="http://www.wpkg.org/packages" | ||
+ | xmlns:wpkg="http://www.wpkg.org/wpkg" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" | ||
+ | xsi:schemaLocation="http://www.wpkg.org/packages xsd/packages.xsd"> | ||
+ | |||
+ | <package | ||
+ | id="identd" | ||
+ | name="retina_scan_identd" | ||
+ | revision="%version%" | ||
+ | priority="10" | ||
+ | reboot="false"> | ||
+ | |||
+ | <variable name="version" value="0.3.0" /> <!-- for easier upgrading --> | ||
+ | |||
+ | <variable name="PKG_DESTINATION" value="%PROGRAMFILES%\Nockmaar\Retina Scan" /> | ||
+ | <variable name="PKG_DESTINATION" value="%PROGRAMFILES(x86)%\Nockmaar\Retina Scan" $ | ||
+ | |||
+ | <check type="uninstall" condition="exists" path="Retina Scan Version 0.3.0" /> | ||
+ | |||
+ | <!-- install the software --> | ||
+ | <install cmd='"%SOFTWARE%\identd\retina-scan-%version%.exe" /sp- /silent /norestart' /> | ||
+ | <!-- add identd to the firewall --> | ||
+ | <install cmd='netsh advfirewall firewall add rule name="ident" dir=in action=allow prog$ | ||
+ | <!-- add service --> | ||
+ | <install cmd='sc create identd binpath= "%PKG_DESTINATION%\identd.exe" start= auto' /> | ||
+ | <install cmd='net start identd' /> | ||
+ | |||
+ | <upgrade cmd='"%SOFTWARE%\identd\retina-scan-%version%.exe" /sp- /silent /norestart' /> | ||
+ | |||
+ | <remove cmd='"%PKG_DESTINATION%\unins000.exe" /sp- /silent /norestart' /> | ||
+ | |||
+ | </package> | ||
+ | </packages:packages> | ||
+ | |||
</source> | </source> | ||
[[Category:Silent Installers]] | [[Category:Silent Installers]] |
Revision as of 10:11, 31 July 2014
This is a silent installer and uninstaller for Retina Scan Identd.
Retina Scan Identd is a RFC 1413 Ident Server for Windows XP. You may use it with Dansguardian, Squid, IRC, etc.
You may have to manually configure Windows firewall (not tested).
<package id="retina_scan_identd" name="retina_scan_identd" revision="1" priority="0" reboot="false">
<check type="uninstall" condition="exists" path="Retina Scan Version 0.3.0" />
<install cmd='"%SOFTWARE%\retina-scan-0.3.0.exe" /sp- /silent' />
<upgrade cmd='"%SOFTWARE%\retina-scan-0.3.0.exe" /sp- /silent' />
<remove cmd='"%PROGRAMFILES%\Nockmaar\Retina Scan\unins000.exe" /sp- /silent /norestart' />
</package>
For windows 7 installs, we have written the following code. It will add the software to the firewall and make an autostart service (it should not need restarting after first install either)
<?xml version="1.0" encoding="UTF-8"?>
<!-- CHANGE LOG -----------------------------------------------
DATE USER EDIT
--------------------------------------------------------------->
<packages:packages xmlns:packages="http://www.wpkg.org/packages"
xmlns:wpkg="http://www.wpkg.org/wpkg" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
xsi:schemaLocation="http://www.wpkg.org/packages xsd/packages.xsd">
<package
id="identd"
name="retina_scan_identd"
revision="%version%"
priority="10"
reboot="false">
<variable name="version" value="0.3.0" /> <!-- for easier upgrading -->
<variable name="PKG_DESTINATION" value="%PROGRAMFILES%\Nockmaar\Retina Scan" />
<variable name="PKG_DESTINATION" value="%PROGRAMFILES(x86)%\Nockmaar\Retina Scan" $
<check type="uninstall" condition="exists" path="Retina Scan Version 0.3.0" />
<!-- install the software -->
<install cmd='"%SOFTWARE%\identd\retina-scan-%version%.exe" /sp- /silent /norestart' />
<!-- add identd to the firewall -->
<install cmd='netsh advfirewall firewall add rule name="ident" dir=in action=allow prog$
<!-- add service -->
<install cmd='sc create identd binpath= "%PKG_DESTINATION%\identd.exe" start= auto' />
<install cmd='net start identd' />
<upgrade cmd='"%SOFTWARE%\identd\retina-scan-%version%.exe" /sp- /silent /norestart' />
<remove cmd='"%PKG_DESTINATION%\unins000.exe" /sp- /silent /norestart' />
</package>
</packages:packages>