Difference between revisions of "Solid Edge"
(Add link to SQL server express 2008) |
(add categories, add new version) |
||
Line 1: | Line 1: | ||
This is a silent installer and deinstaller for '''Solid Edge''', a 3D CAD software from Siemens. More infos from [http://www.plm.automation.siemens.com/en_us/products/velocity/solidedge/index.shtml here]. | This is a silent installer and deinstaller for '''Solid Edge''', a 3D CAD software from Siemens. More infos from [http://www.plm.automation.siemens.com/en_us/products/velocity/solidedge/index.shtml here]. | ||
+ | |||
+ | == Solid Edge 2019 == | ||
+ | I dont have x86 PC, that needed Solid Edge. Because of this here only x64 version, that tested on Windows 10. | ||
+ | <source lang="xml"> | ||
+ | <package | ||
+ | id="solidedge" | ||
+ | name="Siemens Solid Edge" | ||
+ | revision="%PKG_VERSION%" | ||
+ | reboot="false" | ||
+ | priority="0"> | ||
+ | |||
+ | <variable name="PKG_VERSION" value="219.00.00091" /> | ||
+ | <variable name="PKG_SOURCE" value="%SOFTWARE%\Siemens\SolidEdge" architecture="x64" /> | ||
+ | <variable name="PKG_NAME" value="Solid_Edge_Free2D_2019_%PKG_VERSION%.exe" architecture="x64" /> | ||
+ | <variable name="PKG_INSTALL_SWITCH" value="/S /v/qn" /> | ||
+ | <!-- <variable name="PKG_REMOVE_SWITCH" value="/qn" /> | ||
+ | <variable name="PKG_MSI_CODE" value="{C62CE6BD-CC1D-4459-AA70-19295563C462}" /> --> | ||
+ | |||
+ | <check type="uninstall" condition="versiongreaterorequal" path="Siemens Solid Edge .+" value="%PKG_VERSION%" /> | ||
+ | |||
+ | <install cmd='"%PKG_SOURCE%\%PKG_NAME%" %PKG_INSTALL_SWITCH%' /> | ||
+ | |||
+ | <upgrade include='remove' /> | ||
+ | <upgrade include='install' /> | ||
+ | |||
+ | <!-- You can use msi uninstaller if you want. | ||
+ | <remove cmd='msiexec /X %PKG_MSI_CODE% %PKG_REMOVE_SWITCH%'> | ||
+ | <exit code='any' /> | ||
+ | </remove> --> | ||
+ | <remove cmd='wmic product where "name like 'Siemens Solid Edge%%'" call uninstall' /> | ||
+ | </package> | ||
+ | </source> | ||
+ | == Old versions == | ||
Those 4 installers are for the x86 and AMD64 architectures of the software and the maintenance pack. | Those 4 installers are for the x86 and AMD64 architectures of the software and the maintenance pack. | ||
Line 12: | Line 45: | ||
=== Solid Edge 32 === | === Solid Edge 32 === | ||
− | |||
<source lang="xml"> | <source lang="xml"> | ||
<package id="solidedge" | <package id="solidedge" |
Latest revision as of 14:36, 16 May 2020
This is a silent installer and deinstaller for Solid Edge, a 3D CAD software from Siemens. More infos from here.
Contents
Solid Edge 2019
I dont have x86 PC, that needed Solid Edge. Because of this here only x64 version, that tested on Windows 10.
<package
id="solidedge"
name="Siemens Solid Edge"
revision="%PKG_VERSION%"
reboot="false"
priority="0">
<variable name="PKG_VERSION" value="219.00.00091" />
<variable name="PKG_SOURCE" value="%SOFTWARE%\Siemens\SolidEdge" architecture="x64" />
<variable name="PKG_NAME" value="Solid_Edge_Free2D_2019_%PKG_VERSION%.exe" architecture="x64" />
<variable name="PKG_INSTALL_SWITCH" value="/S /v/qn" />
<!-- <variable name="PKG_REMOVE_SWITCH" value="/qn" />
<variable name="PKG_MSI_CODE" value="{C62CE6BD-CC1D-4459-AA70-19295563C462}" /> -->
<check type="uninstall" condition="versiongreaterorequal" path="Siemens Solid Edge .+" value="%PKG_VERSION%" />
<install cmd='"%PKG_SOURCE%\%PKG_NAME%" %PKG_INSTALL_SWITCH%' />
<upgrade include='remove' />
<upgrade include='install' />
<!-- You can use msi uninstaller if you want.
<remove cmd='msiexec /X %PKG_MSI_CODE% %PKG_REMOVE_SWITCH%'>
<exit code='any' />
</remove> -->
<remove cmd='wmic product where "name like 'Siemens Solid Edge%%'" call uninstall' />
</package>
Old versions
Those 4 installers are for the x86 and AMD64 architectures of the software and the maintenance pack. Lastest releases are ST3 and MP08.
Solid Edge ST3 require:
- Windows XP SP3 (refuse install on SP2) or later.
- DirectX 9C (x64 for Solid Edge E64)
- Windows Installer 4.5 (x64 for Solid Edge E64)
- .Net framwork 3.5 SP1
- Microsoft SQL Server 2008 Express
Solid Edge 32
<package id="solidedge"
name="Solid Edge ST3"
revision="1030"
reboot="false"
priority="0">
<check type="logical" condition="or">
<check type="registry" condition="equals" path="HKLM\SOFTWARE\Microsoft\Windows NT\CurrentVersion\ProductName" value="Microsoft Windows 2000" /><!--Solid Edge requiert WinXP SP2 mini-->
<check type="uninstall" condition="exists" path="Solid Edge ST3" />
<check type="registry" condition="equals" path="HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session Manager\Environment\PROCESSOR_ARCHITECTURE" value="AMD64" /><!--si c'est un windows 64bit, skip: j'installe Solid Edge 64bit-->
</check>
<!--deinstall des Versions precedentes evetuellement installees-->
<!--V20 32bit-->
<install cmd='msiexec /qn /x {886F91D5-4B45-45DC-938E-6B0276C6B015}' ><exit code="any" /></install>
<!--ST2 32bit-->
<install cmd='msiexec /qn /x {CC185D10-5C0E-40C3-91F2-63314BB365AF}' ><exit code="any" /></install>
<!--install de la version actuel-->
<install timeout="900" cmd='msiexec /i "%SOFTWARE%\Siemens\Solid Edge\Solid Edge ST3 32-bit\Solid Edge\Solid Edge ST3.msi" USERFILESPEC="%SOFTWARE%\Siemens\Solid Edge\SELicense_V103_flottante.dat" /qn+ /l*v c:\mysilentsetup.log' />
<!--copie des fichiers de licence
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></install> <!-- pour vista et +-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></install> <!-- pour vista et +-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></install> <!-- pour vista et +-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></install> <!-- pour winXP-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></install> <!-- pour winXP-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></install> <!-- pour winXP-->
<!--deinstall de la Version precedente-->
<!--V20 32bit-->
<upgrade cmd='msiexec /qn /x {886F91D5-4B45-45DC-938E-6B0276C6B015}' ><exit code="any" /></upgrade>
<!--ST2 32bit-->
<upgrade cmd='msiexec /qn /x {CC185D10-5C0E-40C3-91F2-63314BB365AF}' ><exit code="any" /></upgrade>
<!--install de la version actuel-->
<upgrade timeout="900" cmd='msiexec /i "%SOFTWARE%\Siemens\Solid Edge\Solid Edge ST3 32-bit\Solid Edge\Solid Edge ST3.msi" USERFILESPEC="%SOFTWARE%\Siemens\Solid Edge\SELicense_V103_flottante.dat" /qn+ /l*v c:\mysilentsetup.log' />
<!--copie des fichiers de licence
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour winXP-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour winXP-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour winXP-->
<remove cmd='msiexec /qn /x {66ED11B7-4988-47FA-BE42-45A3AF0415BC}' />
</package>
Solid Edge 64
<package id="solidedge64"
name="Solid Edge ST3 64-bit"
revision="1030"
reboot="false"
priority="0">
<check type="logical" condition="or">
<check type="registry" condition="equals" path="HKLM\SOFTWARE\Microsoft\Windows NT\CurrentVersion\ProductName" value="Microsoft Windows 2000" /><!--Solid Edge requiert WinXP SP2 mini-->
<check type="registry" condition="equals" path="HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session Manager\Environment\PROCESSOR_ARCHITECTURE" value="x86" /><!--for 64-bit hosts only -->
<check type='uninstall' condition='exists' path='Solid Edge ST3' />
</check>
<!--deinstall des Versions precedentes eventuellement installees-->
<!--V20 32bit-->
<install cmd='msiexec /qn /x {886F91D5-4B45-45DC-938E-6B0276C6B015}'><exit code="any" /></install>
<!-- V20 64bit-->
<install cmd='msiexec /qn /x {6C95407D-1D56-4394-9A04-8ED9A67DF99A}'> <exit code="any" /></install>
<!--ST2 32bit-->
<install cmd='msiexec /qn /x {CC185D10-5C0E-40C3-91F2-63314BB365AF}'><exit code="any" /></install>
<!-- V102 64bit-->
<install cmd='msiexec /qn /x {35A5B689-907E-4052-9855-A7A083B233E9}'> <exit code="any" /></install>
<!--install de la version actuel-->
<install timeout="900" cmd='msiexec /i "%SOFTWARE%\Siemens\Solid Edge\Solid Edge ST3 64-bit\Solid Edge ST3.msi" USERFILESPEC="%SOFTWARE%\Siemens\Solid Edge\SElicense.dat" /qn+ /l*v c:\mysilentsetup.log' />
<!--copie des fichiers de licence-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></install> <!-- pour winXP-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></install> <!-- pour winXP-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></install> <!-- pour winXP-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></install> <!-- pour vista et +-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></install> <!-- pour vista et +-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></install> <!-- pour vista et +-->
<!--deinstall des Versions precedentes eventuellement installees-->
<!--V20 32bit-->
<upgrade cmd='msiexec /qn /x {886F91D5-4B45-45DC-938E-6B0276C6B015}'><exit code="any" /></upgrade>
<!-- V20 64bit-->
<upgrade cmd='msiexec /qn /x {6C95407D-1D56-4394-9A04-8ED9A67DF99A}'> <exit code="any" /></upgrade>
<!--ST2 32bit-->
<upgrade cmd='msiexec /qn /x {CC185D10-5C0E-40C3-91F2-63314BB365AF}'><exit code="any" /></upgrade>
<!-- V102 64bit-->
<upgrade cmd='msiexec /qn /x {35A5B689-907E-4052-9855-A7A083B233E9}'> <exit code="any" /></upgrade>
<!--install de la version actuel-->
<upgrade timeout="900" cmd='msiexec /i "%SOFTWARE%\Siemens\Solid Edge\Solid Edge ST3 64-bit\Solid Edge ST3.msi" USERFILESPEC="%SOFTWARE%\Siemens\Solid Edge\SElicense.dat" /qn+ /l*v c:\mysilentsetup.log' />
<!--copie des fichiers de licence-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour winXP-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour winXP-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour winXP-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +-->
<remove cmd='msiexec /qn /x{35A5B689-907E-4052-9855-A7A083B233E9}' />
</package>
Maintenance pack 32
<package id="solidedge_sp"
name="MP08 pour Solid Edge ST3"
revision="10308"
reboot="false"
priority="0">
<check type="logical" condition="or">
<check type="registry" condition="equals" path="HKLM\SOFTWARE\Microsoft\Windows NT\CurrentVersion\ProductName" value="Microsoft Windows 2000" /><!--Solid Edge requiert WinXP SP3 mini-->
<check type="registry" condition="equals" path="HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session Manager\Environment\PROCESSOR_ARCHITECTURE" value="AMD64" /><!--si c'est un windows 64bit, skip: j'installe le SP de Solid Edge 64bit-->
<check type="registry" condition="equals" path="HKEY_LOCAL_MACHINE\SOFTWARE\Unigraphics Solutions\Solid Edge\Version 103\CurrentVersion\Build" value="103.00.08.06"/>
</check>
<!--copie des fichiers de licence-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour vista et +-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour vista et +-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour vista et +-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour winXP-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour winXP-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour winXP-->
<!--install du service pack-->
<install timeout="600" cmd='"%SOFTWARE%\Siemens\Solid Edge\MP08 pour Solid Edge ST3\SE32MP8\setup.exe" -S' />
<!--copie des fichiers de licence-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour vista et +-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour vista et +-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour vista et +-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour winXP-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour winXP-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour winXP-->
<!--install du service pack-->
<upgrade timeout="600" cmd='"%SOFTWARE%\Siemens\Solid Edge\MP08 pour Solid Edge ST3\SE32MP8\setup.exe" -S' />
</package>
Maintenance pack 64
<package id="solidedge_sp64"
name="MP08 pour Solid Edge ST3 64-bit"
revision="10308"
reboot="false"
priority="0">
<check type="logical" condition="or">
<check type="registry" condition="equals" path="HKLM\SOFTWARE\Microsoft\Windows NT\CurrentVersion\ProductName" value="Microsoft Windows 2000" /><!--Solid Edge requiert WinXP SP3 mini-->
<check type="registry" condition="equals" path="HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session Manager\Environment\PROCESSOR_ARCHITECTURE" value="x86" /><!--for 64-bit hosts only -->
<check type="registry" condition="equals" path="HKEY_LOCAL_MACHINE\SOFTWARE\Unigraphics Solutions\Solid Edge\Version 103\CurrentVersion\Build" value="103.00.08.06 x64"/>
</check>
<!--copie des fichiers de licence-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></install> <!-- pour vista et +-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></install> <!-- pour vista et +-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></install> <!-- pour vista et +-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour winXP-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour winXP-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour winXP-->
<!--install du service pack-->
<install timeout="600" cmd='"%SOFTWARE%\Siemens\Solid Edge\MP08 pour Solid Edge ST3\SE64MP8\setup.exe" -s' />
<!--copie des fichiers de licence-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' ><exit code="any" /></upgrade>
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour winXP-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour winXP-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour winXP-->
<!--install du service pack-->
<upgrade timeout="600" cmd='"%SOFTWARE%\Siemens\Solid Edge\MP08 pour Solid Edge ST3\SE64MP8\setup.exe" -s' />
</package>
those files have to be created in "C:\Program Files\Solid Edge ST3\Program\":
SE_flottante.bat:
copy SElicense_flottante.dat SElicense.dat /Y
SE_2D.bat:
copy SElicense_2D.dat SElicense.dat /Y
The files SElicense.* are provided by Siemens.
The maintenance packs SE32MPXX.exe and SE64MPXX.exe must be unzipped with 7-Zip.
SEviewer.exe.lnk is a link to the file "C:\Program Files\Solid Edge STx\Program\seviewer.exe" for x86 architecture,
SEviewer.lnk is a link to the file "C:\Program Files\Solid Edge STx\Program\win32\seviewer.exe" for AMD64 architecture.