Difference between revisions of "ADS 2004A"
From WPKG | Open Source Software Deployment and Distribution
m |
|||
Line 16: | Line 16: | ||
priority="5"> | priority="5"> | ||
<check type="uninstall" condition="exists" path="Advanced Design System 2004A" /> | <check type="uninstall" condition="exists" path="Advanced Design System 2004A" /> | ||
− | <install cmd='\\server\wpkg\MSI\ADS\2004A\setup.exe /s /sms /f1"\\server\wpkg\MSI\ADS\2004A\silent\complete.iss" /v"/qn"'> | + | <install cmd=''''\\server\wpkg\MSI\ADS\2004A\setup.exe /s /sms /f1"\\server\wpkg\MSI\ADS\2004A\silent\complete.iss'''" /v"/qn"'> |
<exit code="0" /> | <exit code="0" /> | ||
</install> | </install> |
Revision as of 20:39, 12 August 2005
Put both cds into one folder on your server.
Using wpkg installed as a service seems not to work with this package! Use the task scheduler for this package!
One reason why it fails may be that the installer is broken - and doesn't work when it is run as a SYSTEM user (which means, the installer only works if it is run as an Administrator). Unfortunately, there is more badly packaged software like that.
excerpt from package.xml:
<package id="ADS2004A" name="Advanced Design System 2004A" revision="1" reboot="false" priority="5"> <check type="uninstall" condition="exists" path="Advanced Design System 2004A" /> <install cmd=''''\\server\wpkg\MSI\ADS\2004A\setup.exe /s /sms /f1"\\server\wpkg\MSI\ADS\2004A\silent\complete.iss'''" /v"/qn"'> <exit code="0" /> </install> <remove cmd="" /> <upgrade cmd="" /> </package>
You may exchange complete.iss with typical.iss.
To customize the response file, refer to Silent Installations.