Difference between revisions of "Solid Edge"
From WPKG | Open Source Software Deployment and Distribution
m (add external link) |
m |
||
Line 1: | Line 1: | ||
− | This is a silent installer and deinstaller for '''Solid Edge''', a 3D CAD software from Siemens. More infos from [http://www.plm.automation.siemens.com/en_us/products/velocity/solidedge/index.shtml here] | + | This is a silent installer and deinstaller for '''Solid Edge''', a 3D CAD software from Siemens. More infos from [http://www.plm.automation.siemens.com/en_us/products/velocity/solidedge/index.shtml here]. |
Those 4 installers are for the x86 and AMD64 architectures of the software and the maintenance pack. | Those 4 installers are for the x86 and AMD64 architectures of the software and the maintenance pack. |
Revision as of 10:40, 31 March 2011
This is a silent installer and deinstaller for Solid Edge, a 3D CAD software from Siemens. More infos from here.
Those 4 installers are for the x86 and AMD64 architectures of the software and the maintenance pack. Lastest releases are ST2 and MP10.
Solid Edge 32
<package id="solidedge"
name="Solid Edge ST2"
revision="1020"
reboot="false"
priority="0">
<check type="logical" condition="or">
<check type="registry" condition="equals" path="HKLM\SOFTWARE\Microsoft\Windows NT\CurrentVersion\ProductName" value="Microsoft Windows 2000" /><!--Solid Edge requiert WinXP SP2 mini-->
<check type="uninstall" condition="exists" path="Solid Edge ST2" />
<check type="registry" condition="equals" path="HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session Manager\Environment\PROCESSOR_ARCHITECTURE" value="AMD64" /><!--si c'est un windows 64bit, skip: j'installe Solid Edge 64bit-->
</check>
<!--deinstall de la Version precedente-->
<install cmd='msiexec /qn /x {886F91D5-4B45-45DC-938E-6B0276C6B015}' ><exit code="any" /></install>
<!--install de la version actuel-->
<install cmd='msiexec /i "%SOFTWARE%\Siemens\Solid Edge\Solid Edge ST2 32-bit\Solid Edge\Solid Edge ST2.msi" USERFILESPEC="%SOFTWARE%\Siemens\Solid Edge\SElicense.dat" /qn+ /l*v c:\mysilentsetup.log' />
<!--copie des fichiers de licence-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%PROG_FILES%\Solid Edge ST2\Program\*.*"' />
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%PROG_FILES%\Solid Edge ST2\Program\*.*"' />
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%PROG_FILES%\Solid Edge ST2\Program\*.*"' />
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%PROG_FILES%\Solid Edge ST2\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code="any" /></install> <!-- pour vista et +-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code="any" /></install> <!-- pour vista et +-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code="any" /></install> <!-- pour vista et +-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code="any" /></install> <!-- pour winXP-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code="any" /></install> <!-- pour winXP-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code="any" /></install> <!-- pour winXP-->
<!--deinstall de la Version precedente-->
<upgrade cmd='msiexec /qn /x {886F91D5-4B45-45DC-938E-6B0276C6B015}' ><exit code="any" /></upgrade>
<!--install de la version actuel-->
<upgrade cmd='msiexec /i "%SOFTWARE%\Siemens\Solid Edge\Solid Edge ST2 32-bit\Solid Edge\Solid Edge ST2.msi" USERFILESPEC="%SOFTWARE%\Siemens\Solid Edge\SElicense.dat" /qn+ /l*v c:\mysilentsetup.log' />
<!--copie des fichiers de licence-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%PROG_FILES%\Solid Edge ST2\Program\*.*"' />
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%PROG_FILES%\Solid Edge ST2\Program\*.*"' />
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%PROG_FILES%\Solid Edge ST2\Program\*.*"' />
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%PROG_FILES%\Solid Edge ST2\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code="any" /></upgrade> <!-- pour winXP-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code="any" /></upgrade> <!-- pour winXP-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code="any" /></upgrade> <!-- pour winXP-->
<remove cmd='msiexec /qn /x {CC185D10-5C0E-40C3-91F2-63314BB365AF}' />
</package>
Solid Edge 64
<package id="solidedge64"
name="Solid Edge ST2 64-bit"
revision="1021"
reboot="false"
priority="0">
<check type="logical" condition="or">
<check type="registry" condition="equals" path="HKLM\SOFTWARE\Microsoft\Windows NT\CurrentVersion\ProductName" value="Microsoft Windows 2000" /><!--Solid Edge requiert WinXP SP2 mini-->
<check type="registry" condition="equals" path="HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session Manager\Environment\PROCESSOR_ARCHITECTURE" value="x86" /><!--for 64-bit hosts only -->
<check type="uninstall" condition="exists" path="Solid Edge ST2" />
</check>
<!--deinstall de la Version precedente-->
<install cmd='msiexec /qn /x {6C95407D-1D56-4394-9A04-8ED9A67DF99A}' > <exit code="any" /></install>
<!--install de la version actuel-->
<install cmd='msiexec /i "%SOFTWARE%\Siemens\Solid Edge\Solid Edge ST2 64-bit\Solid Edge\Solid Edge ST2.msi" USERFILESPEC="%SOFTWARE%\Siemens\Solid Edge\SElicense.dat" /qn+ /l*v c:\mysilentsetup.log' />
<!--copie des fichiers de licence-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%ProgramFiles%\Solid Edge ST2\Program\*.*"' />
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%ProgramFiles%\Solid Edge ST2\Program\*.*"' />
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%ProgramFiles%\Solid Edge ST2\Program\*.*"' />
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%ProgramFiles%\Solid Edge ST2\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code="any" /></install> <!-- pour winXP-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code="any" /></install> <!-- pour winXP-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code="any" /></install> <!-- pour winXP-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code="any" /></install> <!-- pour vista et +-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code="any" /></install> <!-- pour vista et +-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code="any" /></install> <!-- pour vista et +-->
<!--deinstall de la Version precedente-->
<upgrade cmd='msiexec /qn /x {6C95407D-1D56-4394-9A04-8ED9A67DF99A}' ><exit code="any" /></upgrade>
<!--install de la version actuel-->
<upgrade cmd='msiexec /i "%SOFTWARE%\Siemens\Solid Edge\Solid Edge ST2 64-bit\Solid Edge\Solid Edge ST2.msi" USERFILESPEC="%SOFTWARE%\Siemens\Solid Edge\SElicense.dat" /qn+ /l*v c:\mysilentsetup.log' />
<!--copie des fichiers de licence-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%ProgramFiles%\Solid Edge ST2\Program\*.*"' />
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%ProgramFiles%\Solid Edge ST2\Program\*.*"' />
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%ProgramFiles%\Solid Edge ST2\Program\*.*"' />
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%ProgramFiles%\Solid Edge ST2\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code="any" /></upgrade> <!-- pour winXP-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code="any" /></upgrade> <!-- pour winXP-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code="any" /></upgrade> <!-- pour winXP-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +-->
<remove cmd='msiexec /qn /x{35A5B689-907E-4052-9855-A7A083B233E9}' />
</package>
Maintenance pack 32
<package id="solidedge_sp"
name="MP10 pour Solid Edge ST2"
revision="10210"
reboot="false"
priority="0">
<check type="logical" condition="or">
<check type="registry" condition="equals" path="HKLM\SOFTWARE\Microsoft\Windows NT\CurrentVersion\ProductName" value="Microsoft Windows 2000" /><!--Solid Edge requiert WinXP SP2 mini-->
<check type="registry" condition="equals" path="HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session Manager\Environment\PROCESSOR_ARCHITECTURE" value="AMD64" /><!--si c'est un windows 64bit, skip: j'installe le SP de Solid Edge 64bit-->
<check type="registry" condition="equals" path="HKEY_LOCAL_MACHINE\SOFTWARE\Unigraphics Solutions\Solid Edge\Version 102\CurrentVersion\Build" value="102.00.10.04"/>
</check>
<!--copie des fichiers de licence-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%PROG_FILES%\Solid Edge ST2\Program\*.*"' />
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%PROG_FILES%\Solid Edge ST2\Program\*.*"' />
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%PROG_FILES%\Solid Edge ST2\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour vista et +-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour vista et +-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour vista et +-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour winXP-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour winXP-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour winXP-->
<!--install du service pack-->
<install cmd='"%SOFTWARE%\Siemens\Solid Edge\MP10 pour Solid Edge ST2\SE32MP10\setup.exe" -S' />
<!--install du service pack-->
<upgrade cmd='"%SOFTWARE%\Siemens\Solid Edge\MP10 pour Solid Edge ST2\SE32MP10\setup.exe" -S' />
<!--copie des fichiers de licence-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%PROG_FILES%\Solid Edge ST2\Program\*.*"' />
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%PROG_FILES%\Solid Edge ST2\Program\*.*"' />
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%PROG_FILES%\Solid Edge ST2\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour vista et +-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour vista et +-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour vista et +-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour winXP-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour winXP-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour winXP-->
</package>
Maintenance pack 64
<package id="solidedge_sp64"
name="MP10 pour Solid Edge ST2 64-bit"
revision="10210"
reboot="false"
priority="0">
<check type="logical" condition="or">
<check type="registry" condition="equals" path="HKLM\SOFTWARE\Microsoft\Windows NT\CurrentVersion\ProductName" value="Microsoft Windows 2000" /><!--Solid Edge requiert WinXP SP2 mini-->
<check type="registry" condition="equals" path="HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session Manager\Environment\PROCESSOR_ARCHITECTURE" value="x86" /><!--for 64-bit hosts only -->
<check type="registry" condition="equals" path="HKEY_LOCAL_MACHINE\SOFTWARE\Unigraphics Solutions\Solid Edge\Version 102\CurrentVersion\Build" value="102.00.10.04 x64"/>
</check>
<!--copie des fichiers de licence-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%ProgramFiles%\Solid Edge ST2\Program\*.*"' />
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%ProgramFiles%\Solid Edge ST2\Program\*.*"' />
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%ProgramFiles%\Solid Edge ST2\Program\*.*"' />
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%ProgramFiles%\Solid Edge ST2\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code="any" /></install> <!-- pour vista et +-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code="any" /></install> <!-- pour vista et +-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code="any" /></install> <!-- pour vista et +-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour winXP-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour winXP-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour winXP-->
<!--install du service pack-->
<install cmd='"%SOFTWARE%\Siemens\Solid Edge\MP10 pour Solid Edge ST2\SE64MP10\setup.exe" -s' />
<!--copie des fichiers de licence-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%ProgramFiles%\Solid Edge ST2\Program\*.*"' />
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%ProgramFiles%\Solid Edge ST2\Program\*.*"' />
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%ProgramFiles%\Solid Edge ST2\Program\*.*"' />
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%ProgramFiles%\Solid Edge ST2\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour winXP-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour winXP-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour winXP-->
<!--install du service pack-->
<upgrade cmd='"%SOFTWARE%\Siemens\Solid Edge\MP10 pour Solid Edge ST2\SE64MP10\setup.exe" -s' />
</package>
those files have to be created in "C:\Program Files\Solid Edge ST2\Program\": SE_flottante.bat:
copy SElicense_flottante.dat SElicense.dat /Y
SE_2D.bat:
copy SElicense_2D.dat SElicense.dat /Y
The files SElicense.* are provided by Siemens.
The maintenance packs SE32MPXX.exe and SE64MPXX.exe must be unzipped with 7-Zip.
SEviewer.exe.lnk is a link to the file "C:\Program Files\Solid Edge ST2\Program\seviewer.exe" for x86 architecture,
SEviewer.lnk is a link to the file "C:\Program Files\Solid Edge ST2\Program\win32\seviewer.exe" for AMD64 architecture.