Solid Edge

This is a silent installer and deinstaller for Solid Edge, a 3D CAD software from Siemens. More infos from here.

Solid Edge 2019

I dont have x86 PC, that needed Solid Edge. Because of this here only x64 version, that tested on Windows 10.

 
<package
	id="solidedge"
	name="Siemens Solid Edge"
	revision="%PKG_VERSION%"
	reboot="false"
	priority="0">
	
	<variable name="PKG_VERSION"		value="219.00.00091" />
	<variable name="PKG_SOURCE"		value="%SOFTWARE%\Siemens\SolidEdge" architecture="x64" />
	<variable name="PKG_NAME"		value="Solid_Edge_Free2D_2019_%PKG_VERSION%.exe" architecture="x64" />
	<variable name="PKG_INSTALL_SWITCH"	value="/S /v/qn" />
<!--	<variable name="PKG_REMOVE_SWITCH"	value="/qn" />
	<variable name="PKG_MSI_CODE"		value="{C62CE6BD-CC1D-4459-AA70-19295563C462}" /> -->

	<check type="uninstall" condition="versiongreaterorequal" path="Siemens Solid Edge .+" value="%PKG_VERSION%" />
	
	<install cmd='"%PKG_SOURCE%\%PKG_NAME%" %PKG_INSTALL_SWITCH%' />

	<upgrade include='remove' />		
	<upgrade include='install' />

<!-- 	You can use msi uninstaller if you want.
	<remove cmd='msiexec /X %PKG_MSI_CODE% %PKG_REMOVE_SWITCH%'>
			<exit code='any' />
	</remove>	-->
	<remove cmd='wmic product where "name like &apos;Siemens Solid Edge%%&apos;" call uninstall' /> 	
</package>

Old versions

Those 4 installers are for the x86 and AMD64 architectures of the software and the maintenance pack. Lastest releases are ST3 and MP08.

Solid Edge ST3 require:

  • Windows XP SP3 (refuse install on SP2) or later.
  • DirectX 9C (x64 for Solid Edge E64)
  • Windows Installer 4.5 (x64 for Solid Edge E64)
  • .Net framwork 3.5 SP1
  • Microsoft SQL Server 2008 Express

Solid Edge 32

 
<package id="solidedge"
 name="Solid Edge ST3" 
 revision="1030" 
 reboot="false" 
 priority="0">
<check type="logical" condition="or">
    <check type="registry"  condition="equals" path="HKLM\SOFTWARE\Microsoft\Windows NT\CurrentVersion\ProductName" value="Microsoft Windows 2000" /><!--Solid Edge requiert WinXP SP2 mini-->
    <check type="uninstall" condition="exists" path="Solid Edge ST3" />
    <check type="registry"  condition="equals" path="HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session Manager\Environment\PROCESSOR_ARCHITECTURE" value="AMD64" /><!--si c'est un windows 64bit, skip: j'installe Solid Edge 64bit-->
</check>
<!--deinstall des Versions precedentes evetuellement installees-->
<!--V20 32bit-->
 <install cmd='msiexec /qn /x {886F91D5-4B45-45DC-938E-6B0276C6B015}' ><exit code="any" /></install>
<!--ST2 32bit-->
 <install cmd='msiexec /qn /x {CC185D10-5C0E-40C3-91F2-63314BB365AF}' ><exit code="any" /></install>
<!--install de la version actuel-->
 <install timeout="900" cmd='msiexec /i "%SOFTWARE%\Siemens\Solid Edge\Solid Edge ST3 32-bit\Solid Edge\Solid Edge ST3.msi" USERFILESPEC="%SOFTWARE%\Siemens\Solid Edge\SELicense_V103_flottante.dat" /qn+ /l*v c:\mysilentsetup.log' />
<!--copie des fichiers de licence
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></install>        <!-- pour vista et +-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></install> <!-- pour vista et +-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></install>                   <!-- pour vista et +-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></install>        <!-- pour winXP-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></install> <!-- pour winXP-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></install>                   <!-- pour winXP-->

<!--deinstall de la Version precedente-->
<!--V20 32bit-->
 <upgrade cmd='msiexec /qn /x {886F91D5-4B45-45DC-938E-6B0276C6B015}' ><exit code="any" /></upgrade>
<!--ST2 32bit-->
 <upgrade cmd='msiexec /qn /x {CC185D10-5C0E-40C3-91F2-63314BB365AF}' ><exit code="any" /></upgrade>
<!--install de la version actuel-->
 <upgrade timeout="900" cmd='msiexec /i "%SOFTWARE%\Siemens\Solid Edge\Solid Edge ST3 32-bit\Solid Edge\Solid Edge ST3.msi" USERFILESPEC="%SOFTWARE%\Siemens\Solid Edge\SELicense_V103_flottante.dat" /qn+ /l*v c:\mysilentsetup.log' />
<!--copie des fichiers de licence
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade>        <!-- pour vista et +-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade>                   <!-- pour vista et +-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade>        <!-- pour winXP-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour winXP-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade>                   <!-- pour winXP-->

<remove cmd='msiexec /qn /x {66ED11B7-4988-47FA-BE42-45A3AF0415BC}' />
</package>

Solid Edge 64

<package id="solidedge64" 
 name="Solid Edge ST3 64-bit" 
 revision="1030" 
 reboot="false" 
 priority="0">
<check type="logical" condition="or">
    <check type="registry"  condition="equals" path="HKLM\SOFTWARE\Microsoft\Windows NT\CurrentVersion\ProductName" value="Microsoft Windows 2000" /><!--Solid Edge requiert WinXP SP2 mini-->
    <check type="registry"  condition="equals" path="HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session Manager\Environment\PROCESSOR_ARCHITECTURE" value="x86" /><!--for 64-bit hosts only -->
    <check type='uninstall' condition='exists' path='Solid Edge ST3' />
</check>
<!--deinstall des Versions precedentes eventuellement installees-->
<!--V20 32bit-->
 <install cmd='msiexec /qn /x {886F91D5-4B45-45DC-938E-6B0276C6B015}'><exit code="any" /></install>
<!-- V20 64bit-->
 <install cmd='msiexec /qn /x {6C95407D-1D56-4394-9A04-8ED9A67DF99A}'> <exit code="any" /></install>
<!--ST2 32bit-->
 <install cmd='msiexec /qn /x {CC185D10-5C0E-40C3-91F2-63314BB365AF}'><exit code="any" /></install>
<!-- V102 64bit-->
 <install cmd='msiexec /qn /x {35A5B689-907E-4052-9855-A7A083B233E9}'> <exit code="any" /></install>
<!--install de la version actuel-->
 <install timeout="900" cmd='msiexec /i "%SOFTWARE%\Siemens\Solid Edge\Solid Edge ST3 64-bit\Solid Edge ST3.msi" USERFILESPEC="%SOFTWARE%\Siemens\Solid Edge\SElicense.dat" /qn+ /l*v c:\mysilentsetup.log' />
<!--copie des fichiers de licence-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></install>        <!-- pour winXP-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></install> <!-- pour winXP-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></install>                   <!-- pour winXP-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></install>        <!-- pour vista et +-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></install> <!-- pour vista et +-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></install>                   <!-- pour vista et +-->

<!--deinstall des Versions precedentes eventuellement installees-->
<!--V20 32bit-->
 <upgrade cmd='msiexec /qn /x {886F91D5-4B45-45DC-938E-6B0276C6B015}'><exit code="any" /></upgrade>
<!-- V20 64bit-->
 <upgrade cmd='msiexec /qn /x {6C95407D-1D56-4394-9A04-8ED9A67DF99A}'> <exit code="any" /></upgrade>
<!--ST2 32bit-->
 <upgrade cmd='msiexec /qn /x {CC185D10-5C0E-40C3-91F2-63314BB365AF}'><exit code="any" /></upgrade>
<!-- V102 64bit-->
 <upgrade cmd='msiexec /qn /x {35A5B689-907E-4052-9855-A7A083B233E9}'> <exit code="any" /></upgrade>
<!--install de la version actuel-->
 <upgrade timeout="900" cmd='msiexec /i "%SOFTWARE%\Siemens\Solid Edge\Solid Edge ST3 64-bit\Solid Edge ST3.msi" USERFILESPEC="%SOFTWARE%\Siemens\Solid Edge\SElicense.dat" /qn+ /l*v c:\mysilentsetup.log' />
<!--copie des fichiers de licence-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade>        <!-- pour winXP-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour winXP-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade>                   <!-- pour winXP-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade>        <!-- pour vista et +-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade>                   <!-- pour vista et +-->

 <remove cmd='msiexec /qn /x{35A5B689-907E-4052-9855-A7A083B233E9}' />

</package>

Maintenance pack 32

<package id="solidedge_sp" 
 name="MP08 pour Solid Edge ST3" 
 revision="10308" 
 reboot="false" 
 priority="0">
<check type="logical" condition="or">
    <check type="registry"  condition="equals" path="HKLM\SOFTWARE\Microsoft\Windows NT\CurrentVersion\ProductName" value="Microsoft Windows 2000" /><!--Solid Edge requiert WinXP SP3 mini-->
    <check type="registry"  condition="equals" path="HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session Manager\Environment\PROCESSOR_ARCHITECTURE" value="AMD64" /><!--si c'est un windows 64bit, skip: j'installe le SP de Solid Edge 64bit-->
    <check type="registry" condition="equals" path="HKEY_LOCAL_MACHINE\SOFTWARE\Unigraphics Solutions\Solid Edge\Version 103\CurrentVersion\Build" value="103.00.08.06"/>
</check>
<!--copie des fichiers de licence-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install>        <!-- pour vista et +-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour vista et +-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install>                    <!-- pour vista et +-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install>        <!-- pour winXP-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour winXP-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install>                    <!-- pour winXP-->
<!--install du service pack-->
 <install timeout="600" cmd='"%SOFTWARE%\Siemens\Solid Edge\MP08 pour Solid Edge ST3\SE32MP8\setup.exe" -S' />

<!--copie des fichiers de licence-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade>        <!-- pour vista et +-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour vista et +-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade>                    <!-- pour vista et +-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade>        <!-- pour winXP-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour winXP-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade>                    <!-- pour winXP-->
<!--install du service pack-->
 <upgrade timeout="600" cmd='"%SOFTWARE%\Siemens\Solid Edge\MP08 pour Solid Edge ST3\SE32MP8\setup.exe" -S' />

 </package>

Maintenance pack 64

<package id="solidedge_sp64" 
 name="MP08 pour Solid Edge ST3 64-bit" 
 revision="10308" 
 reboot="false" 
 priority="0">
<check type="logical" condition="or">
    <check type="registry"  condition="equals" path="HKLM\SOFTWARE\Microsoft\Windows NT\CurrentVersion\ProductName" value="Microsoft Windows 2000" /><!--Solid Edge requiert WinXP SP3 mini-->
    <check type="registry"  condition="equals" path="HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session Manager\Environment\PROCESSOR_ARCHITECTURE" value="x86" /><!--for 64-bit hosts only -->
    <check type="registry" condition="equals" path="HKEY_LOCAL_MACHINE\SOFTWARE\Unigraphics Solutions\Solid Edge\Version 103\CurrentVersion\Build" value="103.00.08.06 x64"/>
</check>
<!--copie des fichiers de licence-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></install>        <!-- pour vista et +-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></install> <!-- pour vista et +-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></install>                   <!-- pour vista et +-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install>        <!-- pour winXP-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour winXP-->
 <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install>                   <!-- pour winXP-->
<!--install du service pack-->
 <install timeout="600" cmd='"%SOFTWARE%\Siemens\Solid Edge\MP08 pour Solid Edge ST3\SE64MP8\setup.exe" -s' />

<!--copie des fichiers de licence-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' ><exit code="any" /></upgrade>
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%ProgramFiles%\Solid Edge ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade>        <!-- pour vista et +-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST3\*.*"' ><exit code="any" /></upgrade>                   <!-- pour vista et +-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade>        <!-- pour winXP-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour winXP-->
 <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade>                   <!-- pour winXP-->
<!--install du service pack-->
 <upgrade timeout="600" cmd='"%SOFTWARE%\Siemens\Solid Edge\MP08 pour Solid Edge ST3\SE64MP8\setup.exe" -s' />

 </package>

those files have to be created in "C:\Program Files\Solid Edge ST3\Program\":

SE_flottante.bat:

copy SElicense_flottante.dat SElicense.dat /Y

SE_2D.bat:

copy SElicense_2D.dat SElicense.dat /Y

The files SElicense.* are provided by Siemens.
The maintenance packs SE32MPXX.exe and SE64MPXX.exe must be unzipped with 7-Zip.
SEviewer.exe.lnk is a link to the file "C:\Program Files\Solid Edge STx\Program\seviewer.exe" for x86 architecture,
SEviewer.lnk is a link to the file "C:\Program Files\Solid Edge STx\Program\win32\seviewer.exe" for AMD64 architecture.