Changes

Jump to: navigation, search

Solid Edge

1,576 bytes added, 12:54, 30 September 2011
no edit summary
Those 4 installers are for the x86 and AMD64 architectures of the software and the maintenance pack.
Lastest releases are ST2 ST3 and MP10MP08.Solid Edge ST3 require:- Windows XP SP3 (refuse install on SP2) or later.- DirectX 9C (x64 for Solid Edge E64)- Windows Installer 4.5 (x64 for Solid Edge E64)- .Net framwork 3.5 SP1- Microsoft SQL Server 2008 Express
=== Solid Edge 32 ===
<source lang="xml">
<package id="solidedge"
name="Solid Edge ST2ST3" revision="10201030"
reboot="false"
priority="0">
<check type="logical" condition="or">
<check type="registry" condition="equals" path="HKLM\SOFTWARE\Microsoft\Windows NT\CurrentVersion\ProductName" value="Microsoft Windows 2000" /><!--Solid Edge requiert WinXP SP2 mini-->
<check type="uninstall" condition="exists" path="Solid Edge ST2ST3" />
<check type="registry" condition="equals" path="HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session Manager\Environment\PROCESSOR_ARCHITECTURE" value="AMD64" /><!--si c'est un windows 64bit, skip: j'installe Solid Edge 64bit-->
</check>
<!--deinstall de la Version precedentedes Versions precedentes evetuellement installees--><!--V20 32bit-->
<install cmd='msiexec /qn /x {886F91D5-4B45-45DC-938E-6B0276C6B015}' ><exit code="any" /></install>
<!--ST2 32bit-->
<install cmd='msiexec /qn /x {CC185D10-5C0E-40C3-91F2-63314BB365AF}' ><exit code="any" /></install>
<!--install de la version actuel-->
<install timeout="900" cmd='msiexec /i "%SOFTWARE%\Siemens\Solid Edge\Solid Edge ST2 ST3 32-bit\Solid Edge\Solid Edge ST2ST3.msi" USERFILESPEC="%SOFTWARE%\Siemens\Solid Edge\SElicenseSELicense_V103_flottante.dat" /qn+ /l*v c:\mysilentsetup.log' /><!--copie des fichiers de licence--> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%PROG_FILES%\Solid Edge ST2ST3\Program\*.*"' />--> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%PROG_FILES%\Solid Edge ST2ST3\Program\*.*"' /> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%PROG_FILES%\Solid Edge ST2ST3\Program\*.*"' /> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%PROG_FILES%\Solid Edge ST2ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code="any" /></install> <!-- pour vista et +--> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code="any" /></install> <!-- pour vista et +--> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code="any" /></install> <!-- pour vista et +--> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code="any" /></install> <!-- pour winXP--> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code="any" /></install> <!-- pour winXP--> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code="any" /></install> <!-- pour winXP-->
<!--deinstall de la Version precedente-->
<!--V20 32bit-->
<upgrade cmd='msiexec /qn /x {886F91D5-4B45-45DC-938E-6B0276C6B015}' ><exit code="any" /></upgrade>
<!--ST2 32bit-->
<upgrade cmd='msiexec /qn /x {CC185D10-5C0E-40C3-91F2-63314BB365AF}' ><exit code="any" /></upgrade>
<!--install de la version actuel-->
<upgrade timeout="900" cmd='msiexec /i "%SOFTWARE%\Siemens\Solid Edge\Solid Edge ST2 ST3 32-bit\Solid Edge\Solid Edge ST2ST3.msi" USERFILESPEC="%SOFTWARE%\Siemens\Solid Edge\SElicenseSELicense_V103_flottante.dat" /qn+ /l*v c:\mysilentsetup.log' /><!--copie des fichiers de licence--> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%PROG_FILES%\Solid Edge ST2ST3\Program\*.*"' />--> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%PROG_FILES%\Solid Edge ST2ST3\Program\*.*"' /> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%PROG_FILES%\Solid Edge ST2ST3\Program\*.*"' /> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%PROG_FILES%\Solid Edge ST2ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +--> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +--> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +--> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour winXP--> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour winXP--> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour winXP-->
<remove cmd='msiexec /qn /x {CC185D1066ED11B7-5C0E4988-40C347FA-91F2BE42-63314BB365AF45A3AF0415BC}' /></package></source>
=== Solid Edge 64 ===
<source lang="xml">
<package id="solidedge64"
name="Solid Edge ST2 ST3 64-bit" revision="10211030"
reboot="false"
priority="0">
<check type="registry" condition="equals" path="HKLM\SOFTWARE\Microsoft\Windows NT\CurrentVersion\ProductName" value="Microsoft Windows 2000" /><!--Solid Edge requiert WinXP SP2 mini-->
<check type="registry" condition="equals" path="HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session Manager\Environment\PROCESSOR_ARCHITECTURE" value="x86" /><!--for 64-bit hosts only -->
<check type="'uninstall" ' condition="'exists" ' path="'Solid Edge ST2" ST3' />
</check>
<!--deinstall de la Version precedentedes Versions precedentes eventuellement installees--><!--V20 32bit--> <install cmd='msiexec /qn /x {886F91D5-4B45-45DC-938E-6B0276C6B015}'><exit code="any" /></install><!-- V20 64bit--> <install cmd='msiexec /qn /x {6C95407D-1D56-4394-9A04-8ED9A67DF99A}'> <exit code="any" /></install><!--ST2 32bit--> <install cmd='msiexec /qn /x {CC185D10-5C0E-40C3-91F2-63314BB365AF}'><exit code="any" /></install><!-- V102 64bit--> <install cmd='msiexec /qn /x {35A5B689-907E-4052-9855-A7A083B233E9}' > <exit code="any" /></install>
<!--install de la version actuel-->
<install timeout="900" cmd='msiexec /i "%SOFTWARE%\Siemens\Solid Edge\Solid Edge ST2 ST3 64-bit\Solid Edge\Solid Edge ST2ST3.msi" USERFILESPEC="%SOFTWARE%\Siemens\Solid Edge\SElicense.dat" /qn+ /l*v c:\mysilentsetup.log' />
<!--copie des fichiers de licence-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%ProgramFiles%\Solid Edge ST2ST3\Program\*.*"' /> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%ProgramFiles%\Solid Edge ST2ST3\Program\*.*"' /> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%ProgramFiles%\Solid Edge ST2ST3\Program\*.*"' /> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%ProgramFiles%\Solid Edge ST2ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code="any" /></install> <!-- pour winXP--> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code="any" /></install> <!-- pour winXP--> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code="any" /></install> <!-- pour winXP--> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code="any" /></install> <!-- pour vista et +--> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code="any" /></install> <!-- pour vista et +--> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code="any" /></install> <!-- pour vista et +-->
<!--deinstall de la Version precedentedes Versions precedentes eventuellement installees--><!--V20 32bit--> <upgrade cmd='msiexec /qn /x {886F91D5-4B45-45DC-938E-6B0276C6B015}'><exit code="any" /></upgrade><!-- V20 64bit--> <upgrade cmd='msiexec /qn /x {6C95407D-1D56-4394-9A04-8ED9A67DF99A}'> <exit code="any" /></upgrade><!--ST2 32bit--> <upgrade cmd='msiexec /qn /x {CC185D10-5C0E-40C3-91F2-63314BB365AF}'><exit code="any" /></upgrade><!-- V102 64bit--> <upgrade cmd='msiexec /qn /x {35A5B689-907E-4052-9855-A7A083B233E9}' ><exit code="any" /></upgrade>
<!--install de la version actuel-->
<upgrade timeout="900" cmd='msiexec /i "%SOFTWARE%\Siemens\Solid Edge\Solid Edge ST2 ST3 64-bit\Solid Edge\Solid Edge ST2ST3.msi" USERFILESPEC="%SOFTWARE%\Siemens\Solid Edge\SElicense.dat" /qn+ /l*v c:\mysilentsetup.log' />
<!--copie des fichiers de licence-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%ProgramFiles%\Solid Edge ST2ST3\Program\*.*"' /> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%ProgramFiles%\Solid Edge ST2ST3\Program\*.*"' /> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%ProgramFiles%\Solid Edge ST2ST3\Program\*.*"' /> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%ProgramFiles%\Solid Edge ST2ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour winXP--> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour winXP--> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour winXP--> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +--> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +--> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +-->
<remove cmd='msiexec /qn /x{35A5B689-907E-4052-9855-A7A083B233E9}' />
</package> </source>
=== Maintenance pack 32 ===
<source lang="xml"> <package id="solidedge_sp" name="MP10 MP08 pour Solid Edge ST2ST3" revision="1021010308"
reboot="false"
priority="0">
<check type="logical" condition="or">
<check type="registry" condition="equals" path="HKLM\SOFTWARE\Microsoft\Windows NT\CurrentVersion\ProductName" value="Microsoft Windows 2000" /><!--Solid Edge requiert WinXP SP2 SP3 mini-->
<check type="registry" condition="equals" path="HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session Manager\Environment\PROCESSOR_ARCHITECTURE" value="AMD64" /><!--si c'est un windows 64bit, skip: j'installe le SP de Solid Edge 64bit-->
<check type="registry" condition="equals" path="HKEY_LOCAL_MACHINE\SOFTWARE\Unigraphics Solutions\Solid Edge\Version 102103\CurrentVersion\Build" value="102103.00.1008.0406"/>
</check>
<!--copie des fichiers de licence-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%PROG_FILES%\Solid Edge ST3\Program\*.*"' /> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%PROG_FILES%\Solid Edge ST2ST3\Program\*.*"' /> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%PROG_FILES%\Solid Edge ST2ST3\Program\*.*"' /> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%PROG_FILES%\Solid Edge ST2ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour vista et +--> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour vista et +--> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour vista et +--> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour winXP--> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour winXP--> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour winXP-->
<!--install du service pack-->
<install timeout="600" cmd='"%SOFTWARE%\Siemens\Solid Edge\MP10 MP08 pour Solid Edge ST2ST3\SE32MP10SE32MP8\setup.exe" -S' />
<!--install du service pack-->
<upgrade cmd='"%SOFTWARE%\Siemens\Solid Edge\MP10 pour Solid Edge ST2\SE32MP10\setup.exe" -S' />
<!--copie des fichiers de licence-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%PROG_FILES%\Solid Edge ST2ST3\Program\*.*"' /> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%PROG_FILES%\Solid Edge ST2ST3\Program\*.*"' /> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%PROG_FILES%\Solid Edge ST2ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour vista et +--> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour vista et +--> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour vista et +--> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour winXP--> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour winXP--> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.exe.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour winXP--><!--install du service pack--> <upgrade timeout="600" cmd='"%SOFTWARE%\Siemens\Solid Edge\MP08 pour Solid Edge ST3\SE32MP8\setup.exe" -S' />
</package></source>
=== Maintenance pack 64 ===
<source lang="xml"> <package id="solidedge_sp64" name="MP10 MP08 pour Solid Edge ST2 ST3 64-bit" revision="1021010308"
reboot="false"
priority="0">
<check type="logical" condition="or">
<check type="registry" condition="equals" path="HKLM\SOFTWARE\Microsoft\Windows NT\CurrentVersion\ProductName" value="Microsoft Windows 2000" /><!--Solid Edge requiert WinXP SP2 SP3 mini-->
<check type="registry" condition="equals" path="HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control\Session Manager\Environment\PROCESSOR_ARCHITECTURE" value="x86" /><!--for 64-bit hosts only -->
<check type="registry" condition="equals" path="HKEY_LOCAL_MACHINE\SOFTWARE\Unigraphics Solutions\Solid Edge\Version 102103\CurrentVersion\Build" value="102103.00.1008.04 06 x64"/>
</check>
<!--copie des fichiers de licence-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%ProgramFiles%\Solid Edge ST2ST3\Program\*.*"' /> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%ProgramFiles%\Solid Edge ST2ST3\Program\*.*"' /> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%ProgramFiles%\Solid Edge ST2ST3\Program\*.*"' /> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%ProgramFiles%\Solid Edge ST2ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code="any" /></install> <!-- pour vista et +--> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code="any" /></install> <!-- pour vista et +--> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code="any" /></install> <!-- pour vista et +--> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour winXP--> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour winXP--> <install cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></install> <!-- pour winXP-->
<!--install du service pack-->
<install timeout="600" cmd='"%SOFTWARE%\Siemens\Solid Edge\MP10 MP08 pour Solid Edge ST2ST3\SE64MP10SE64MP8\setup.exe" -s' />
<!--copie des fichiers de licence-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense.dat" "%ProgramFiles%\Solid Edge ST2ST3\Program\*.*"' /> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_2D.dat" "%ProgramFiles%\Solid Edge ST2ST3\Program\*.*"' ><exit code="any" /></upgrade> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SELicense_flottante.dat" "%ProgramFiles%\Solid Edge ST2ST3\Program\*.*"' /> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SE_*.bat" "%ProgramFiles%\Solid Edge ST2ST3\Program\*.*"' />
<!--copie des raccourcis dans le menu demarrer-->
<upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +--> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +--> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\Microsoft\Windows\Start Menu\Programs\Solid Edge ST2ST3\*.*"' ><exit code="any" /></upgrade> <!-- pour vista et +--> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_2D.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour winXP--> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\basculer vers SE_flottante.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour winXP--> <upgrade cmd='xcopy /Y "%SOFTWARE%\Siemens\Solid Edge\SEviewer.lnk" "%ALLUSERSPROFILE%\MENUDM~1\Programmes\Solid Edge ST2ST3\*.*"' ><exit code='0'/><exit code='4'/><exit code='any'/></upgrade> <!-- pour winXP-->
<!--install du service pack-->
<upgrade timeout="600" cmd='"%SOFTWARE%\Siemens\Solid Edge\MP10 MP08 pour Solid Edge ST2ST3\SE64MP10SE64MP8\setup.exe" -s' />
</package>
</source>
 those files have to be created in "C:\Program Files\Solid Edge ST2ST3\Program\": 
SE_flottante.bat:
<source lang="xml">copy SElicense_flottante.dat SElicense.dat /Y </source>
Anonymous user

Navigation menu